WARNING:
ELECTRIC
SHOCK HAZARD
All servicing requiring
access to non-insulated elec-
trical components must be
performed by a factory au-
thorized technician.
DO NOT open any access
panel which requires the use
of tools. Failure to
follow this warning can
result in severe electrical
shock.
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize
this appliance until all
installation instructions are
read and followed. Damage
to the appliance will result if
these instructions are not
followed.
CAUTION:
ELECTRIC
SHOCK HAZARD
Cord -connected units are
equipped with a three-prong
plug for your protection
against electric shock. Never
cut the large round prong
from the plug, or twist a blade
to fit an existing receptacle.
IMPORTANT:
Contact a licensed electrician
to install the correct circuit
and receptacle (cord-
connected units) or to install
and connect electric power
(field-wired units).
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
405 p/n 305101 OpM RCP Refrigerated Cold Pans
INSTALLATION (continued)
ELECTRICAL INSTALLATION
1. Refer to the nameplate. Verify the electrical service power.
Voltage and phase must match the nameplate specifications.
Wiring the unit to the wrong voltage can severely damage the unit,
or cause a significant decrease in performance.
2. Available electrical amperage must meet or exceed the
specifications listed on the specifications sheet provided with the
unit.
a. Units are equipped with a three-prong (grounding) plug for your
protection against electrical shocks. This must be plugged into
a properly grounded matching receptacle.
b. RCP-100 through RCP-600 and RCP-7100 through RCP-7400
are equipped with a NEMA 5-15P plug and require a matching
NEMA 5-15R receptacle.
c. RCP-7500 and RCP-7600 are equipped with a NEMA 5-20P
plug and require a matching NEMA 5-20R receptacle.
GROUND
PIN
NEMA 5-15P
PLUG
NEMA 5-15R
RECEPTACLE
GROUND
PIN
NEMA 5-20P
PLUG
NEMA 5-20R
RECEPTACLE